The machine is applied for coating the organic film, water soluble film and sugar on tablets.
PLC & Touch screen controlled and GMP standard.
Put the tablet or pellet into the coating drum, the tablet or pellet unceasingly moves in the clean and hermetic rotating coating drum. In the movements, with the requests of reasonable process parameters, coating medium is automatically sprayed, at the same time, hot air is supplied under a negative pressure, which is vented out through the tablet or pellet layer from the bottom of the coating medium sprinkled on the tablet or pellet surface gets dried promptly and equally with forming a solid and smooth surface film.
Features:
1. As required by the standard of GMP, the quantitative index instruction operation is applied as possible as it could in the medication production process.
2. Under the streamline diversion plate blender's effect, the prime pistil overturns fluently, exchanges frequently and excludes the collision phenomenon when the prime pistil falls from high, settles the fragment and knocked edge and enhances finished product ratio. Surface of the diversion plate is narrow and small with excluding adherence of dressing to its surface, saving the dressing and improving medication quality.
3. The peristaltic pump
With constant variable precludes return pope. The return radius of the drumvaries any time with pressure change, output and pulp spraying quantity automatically balance, which stabilize the atomization effect, simplify the atomization system, prevent spray gun clogging and save dressing, what's more, it is simple to clean and without any dead corner.
4. The spray guns are especially designed and manufactured for the coating machine, and the atomization is equal, the spraying is large and the universal adjustable nozzle is independent from loading volume.
5. Possess negative pressure display and control inside the coating boiler.
6. Possess supplied hot air's speed display and control
7. Possess spray gun anti-clogging function.
8. The above functions enables related technical parameters to realized quantitative display and control, the SOP operation method formulation turns feasible and uses quantitative index instruction for the operation, consistency of medication quality in every lot is guaranteed with totally in line with the GMP requirements.
9. This equipment has awarded the appraisal by provincial science and technology inspection department.
Item/model |
BG1000 |
BG600 |
BG400 |
BG150 |
BG80 |
BGB40 |
BGB10 |
LoadingCapacity
(kg/batch)
|
1000kg |
600kg |
400kg |
150kg |
80kg |
40kg |
10kg |
Drum Revolution
(r/min) |
2.0-12rpm |
2.0-12
rpm |
0-13rpm |
2.1-14 rpm |
2.0-16 rpm |
2.0-18
rpm |
3.0-19 rpm |
Main Machine Power
|
7.5KW |
4KW |
3KW |
2.2KW |
1.5KW |
1.1KW |
0.55KW |
Diameter of coating drum |
1800mm |
1580mm |
1580mm |
1200mm |
930mm |
780mm |
500mm |
Power of air exhaust cabinet motor |
11KW |
11KW |
7.5KW |
5.5KW |
3KW |
2.2KW |
0.75KW |
Air exhaust flow |
18000m3/h |
15450 m3/h |
10000m3/h |
7419 m3/h |
5268 m3/h |
3517 m3/h |
1285m3/h |
Power of hot air cabinet motor |
7.5KW |
4KW |
2.2KW |
1.5KW |
1.1KW |
0.75KW |
0.37KW |
Hot air flow |
10650 m3/h |
6500 m3/h |
3517 m3/h |
2356 m3/h |
1685 m3/h |
1285 m3/h |
816 m3/h |
Weight of main machine |
2000 kg |
1600 kg |
1000 kg |
850 kg |
600kg |
500kg |
200kg |
Clean air |
Pressure |
0.4MPa |
≥0.4MPa |
≥0.4MPa |
≥0.4MPa |
≥0.4MPa |
≥0.4MPa |
≥0.4MPa |
Air consumption |
2.5m3/min |
2 m3/min |
1.5 m3/min |
0.7
m3/min |
0.35
m3/min |
0.2 m3/min |
0.2 m3/min |